INSIGHTS | October 23, 2026

Below the Threshold: Why Britain’s Smallest Power Generators Face a Four-Year Cyber Security Gap

Key Takeaways

  • A small-scale gas generator was taken offline for four days in July 2026. The UK Government confirmed the incident but has not formally attributed it. [1]
  • Under the Network and Information Systems Regulations 2018, electricity generation is captured only at 2GW cumulative capacity, and the threshold expressly excludes generators that are not connected to a transmission system. [2]
  • On 5 August 2026 the Department for Energy Security and Net Zero and Ofgem confirmed that baseline cyber resilience requirements for all Ofgem licensees will be built on Cyber Essentials Plus, consulted on during 2027 and in place across the sector by the end of 2030. [3]
  • The same government response acknowledges that Cyber Essentials Plus excludes operational technology and lacks controls covering governance, incident response, risk management and supply chain. Its Plus tier applies the same five technical controls as Cyber Essentials with independent testing, rather than extending them. [3] [9]
  • IT and OT segregation was the single most requested additional control among consultation respondents, raised by 18 of the 49 organisations and individuals who replied. [3]

Why This Matters Now

In July 2026 a small-scale British generating asset stopped producing power for four days following a cyber incident. Michael Shanks, Minister of State at the Department for Energy Security and Net Zero, confirmed that the incident had affected a small-scale energy generator, and the Department stated that at no point was the wider energy system at risk. [1] Press reporting linked the intrusion to Iranian-aligned actors, though the UK Government has made no formal attribution.

The detail that matters for security leaders is not the attribution. It is the position of the asset. A four-day outage at a small distribution-connected generator is an outage at something well below the regulatory perimeter drawn in 2018, which means the operator was almost certainly under no statutory cyber resilience obligation at all.

That perimeter is not a historical accident. The Government’s own Energy Sector Cyber Security Strategy states that the NIS Regulations were only ever intended to apply to the most critical operators and therefore do not provide holistic coverage of the energy system. [4] The strategy also commits Government to encourage more reporting of cyber incidents that fall below NIS thresholds, which is a plain acknowledgement that the sub-threshold estate is a blind spot.

The threat is not theoretical. In December 2025 a threat actor targeted around 30 distributed renewable assets in Poland, including wind and solar farms and a combined heat and power plant. Generation and heat supply held, and the plant involved served nearly 500,000 heat customers. What matters is how the attacker got in: internet-exposed firewall appliances without multi-factor authentication, unpatched devices and reused credentials. Most of those routes could have been closed by basic cyber hygiene. A parallel attack the same day on a smaller plant serving 50,000 residents did interrupt cogeneration, shutting down a steam turbine and the water treatment system. [5] [6]

Meanwhile the estate is growing. Government projections cited in the March 2026 consultation put battery storage capacity on a six-fold increase and wind and solar capacity almost tripling by 2030. [5] Ofgem currently regulates just over 1,400 licensed operators, and Government has described the absence of cyber resilience requirements across a large proportion of them as one of two fundamental reform needs. [3]

What the Regulatory Position Actually Is

Schedule 2 of the NIS Regulations 2018 sets the thresholds at which an operator becomes an Operator of Essential Services. For downstream gas and electricity these are as follows.

Essential ServiceElectricityGas (Downstream)
Generation2GW or more (cumulative)N/A
TransmissionMore than 250,000 final customersMore than 250,000 final customers
Offshore Transmission2GW or more (cumulative)N/A
DistributionMore than 250,000 final customersMore than 250,000 final customers
Interconnectors1GW or moreMore than 20M m3 gas per day
SupplyMore than 250,000 final customersMore than 250,000 final customers
Load Control300MW or moreN/A

Source: DESNZ and Ofgem consultation documents, drawn from NIS Regulations 2018 Schedule 2. Generation excludes nuclear generators and generators not connected to a transmission system. Capacity is cumulated across affiliated undertakings. Load control is not yet in force and will be commenced through the Cyber Security and Resilience Bill. [2] [3]

Two features of that table deserve attention. First, generation capacity is cumulated across a corporate group, so a modest site inside a large portfolio can sit above the line while a standalone site of identical rating sits below it. Second, generators not connected to a transmission system are carved out regardless of size, which removes most distribution-connected embedded generation from scope entirely.

Government consulted on this between 27 March and 22 May 2026 and published its response on 5 August 2026. Nineteen respondents told Government that the electricity generation threshold should change. Twenty-one argued that thresholds should be driven by risk or impact rather than by supply or generation volume, and 19 said the sector has become distributed to the point where current thresholds no longer reflect where risk arises. Six respondents proposed specific replacement figures, including 200MW and 500MW for generation. [3]

Government has not adopted a new number. It has commissioned the National Energy System Operator to advise on which services and thresholds should apply, and intends to consult on any revisions during 2027, subject to the Cyber Security and Resilience Bill receiving Royal Assent. The response states that Royal Assent is expected in early 2027, though secondary coverage consistently reports an expectation of late 2026. The Bill completed Lords Second Reading on 14 July 2026 and entered Lords Committee Stage on 1 September 2026. [3] [8]

Alongside that review, Government confirmed it will introduce baseline cyber resilience requirements for all Ofgem licensees, delivered through licence conditions and founded on Cyber Essentials Plus. Ofgem will consult on the detail during 2027. The public commitment is that a baseline level of cyber resilience will be in place across the whole downstream gas and electricity system by the end of 2030. Any intermediate tier between baseline and NIS is expected to be considered only after 2030. [3]

Who is Affected by the Sub-Threshold Gap?

Sub-threshold generators and distributed energy operators. Operators of embedded gas plant, solar, onshore wind, battery storage and long duration storage that fall below 2GW, or that are not transmission-connected, carry no statutory cyber resilience obligation today and will carry none until baseline requirements are implemented through licence conditions. Many of these sites are unmanned and dependent on remote access.

NIS-designated operators. Designation does not insulate a large operator from the gap. NIS requirements apply only to the network and information systems on which the essential service relies, which Government acknowledges leaves ancillary, supporting and back-end systems outside scope. [5] Large operators also depend on smaller counterparties for flexibility, balancing and aggregation.

Aggregators, flexibility platforms and remote service providers. Consultation respondents identified flexibility services, aggregators and orchestration platforms as the most commonly proposed additions to the essential services list, alongside digital and data platforms and remote monitoring and management providers. [3] Some of these organisations will be captured as large load controllers at 300MW of aggregate controllable load. Many will not.

Boards and investors in generation assets. The regulatory floor is now dated and public. A board that waits for 2030 is accepting four years of exposure on an asset class that has already been taken offline once.

What Are the Challenges the 2030 Baseline Does Not Solve?

The most significant issue is that the announced remedy is shaped for information technology, not for the control systems that took the plant offline.

Government has been candid about this. The consultation observed that Cyber Essentials is primarily suitable for IT, that many downstream gas and electricity operators rely on SCADA systems, programmable logic controllers, human machine interfaces and remote telemetry units, and that applying Cyber Essentials controls to those environments can be challenging and in certain circumstances unsuitable. [5] The government response goes further, recognising that Cyber Essentials Plus has limitations for the energy sector in relation to the exclusion of operational technology and the absence of controls for governance, incident response, risk management and supply chain. [3]

Respondents said the same thing with numbers behind it. IT and OT integration or network segmentation was the leading requested addition at 18 respondents, followed by incident response and exercising at 17, remote access management at 13, supply chain visibility at 12 and governance at 10. When asked for alternative frameworks, respondents most often named the NCSC Cyber Assessment Framework at 16 and IEC 62443 at 15, ahead of ISO 27001 at 14. [3] The sector asked for an OT-aware standard. What has been confirmed so far is an IT scheme that Government intends to build on, with the additional controls still to be designed. It is worth being precise about what the Plus tier adds: Cyber Essentials Plus applies the same five technical controls as Cyber Essentials and subjects them to independent technical testing rather than extending them. [9] Choosing Plus over the base scheme raises the assurance level, not the scope.

Three further constraints compound this. Government intends that, where possible, baseline requirements should apply only to systems not already covered by existing cyber resilience obligations, which creates scope boundaries that operators will need to evidence rather than assume. [3] Consultation respondents reported that the prescriptiveness of Cyber Essentials controls and the inability to use compensating controls were common drivers of cost in OT-heavy and legacy environments. [3] And the assurance route for complex estates is still under exploration, with Government committing only to examine the potential of NCSC Cyber Essentials Pathways. [3]

The practical conclusion for a security leader is that compliance and resilience are not the same programme here, and neither of them arrives before 2030.

How IOActive Can Help

The gap this post describes is not a compliance problem yet, which is precisely why it is an assessment problem now. An operator below the 2GW line has no licence condition to evidence against and no NIS designation to scope, so the only reliable way to establish its position is to test the estate against a framework the eventual baseline will have to catch up to.

IOActive has operated in industrial control environments since building the first proof-of-concept worm against the smart grid in 2009 [10], and has helped define standards and best practices including NIST 800-53 and 800-37. The services below map to the specific gaps the 2030 baseline leaves open.

Full Stack Security Assessments

Government has confirmed that Cyber Essentials Plus excludes operational technology and that applying its controls to SCADA systems, programmable logic controllers, human machine interfaces and remote telemetry units can be unsuitable. Our Full Stack assessments examine the whole environment rather than a single layer, covering the controllers and HMIs at distribution-connected sites, the OT/IT boundary, and the cellular and vendor paths that commonly provide unmanned generation assets with connectivity nobody has inventoried. Where the baseline will eventually ask for evidence, an assessment produces it rather than assuming it.

Hardware and Firmware Security Research

The assets in question are largely unmanned and remotely operated, which places the security of the controller and telemetry unit itself in scope rather than only the network around it. Our hardware and firmware research examines the devices deployed at these sites directly, at a depth that network-layer testing cannot reach and that no IT-derived certification scheme currently asks for.

Supply Chain Integrity

Consultation respondents named supply chain visibility among the leading controls missing from Cyber Essentials Plus, and identified aggregators, flexibility platforms and remote monitoring providers as the additions most often proposed to the essential services list. Our Supply Chain Integrity work assesses the posture of technology providers and critical third parties, covering firmware, embedded systems, remote access arrangements and procurement, so that inherited risk is identified before it becomes a shared incident. For operators contracting with aggregators and remote service providers, this is the exposure that sits outside their own perimeter and inside their own outage.

Red Team and Purple Team Services

Incident response and exercising was the second most requested addition to the baseline, at 17 respondents. Adversary simulation is how an operator establishes whether an intrusion at a small asset would be detected and contained before it interrupts generation, rather than assuming the segmentation on the network diagram holds under test.

Advisory Services

The 2027 consultations will ask operators to state which systems fall inside a future baseline, which already sit inside NIS scope, and where residual OT exposure lies. That is a scoping determination an operator has to be able to defend, not describe. Our Advisory Services cover programmatic security review, security programme development and management, and Virtual CISO support, and the output is a documented scope position for each asset, a remediation sequence with named owners and dates, and the evidence pack a board or regulator will ask for.

If you would like to discuss where your generation or distributed energy assets sit against the thresholds described in this post, and what the residual OT exposure looks like, we welcome the conversation.

  1. Establish the regulatory position of every generating asset in the portfolio, including cumulative group capacity and whether the connection is to a transmission or a distribution system, and record the basis for each determination.
  2. Treat the 2030 baseline as a floor rather than a target, and assess the estate against an OT-aware framework such as IEC 62443 or the NCSC Cyber Assessment Framework rather than waiting for licence conditions to be drafted.
  3. Inventory remote access into unmanned sites, including vendor and maintenance pathways, and verify that segmentation between corporate IT and control networks holds under test rather than on the network diagram.
  4. Extend incident response plans to cover loss of generation at a sub-threshold asset, and exercise them, given that incident response and exercising was the second most requested control in the consultation.
  5. Review contractual cyber security obligations with aggregators, flexibility platforms and remote monitoring providers, several of which may be brought into NIS scope during the 2027 review.
  6. Engage with the Ofgem consultation expected during 2027, since the additional controls that sit above Cyber Essentials Plus are still being designed and sector evidence will shape them.

Conclusion

The regulatory perimeter for British electricity generation was drawn around a small number of very large assets in 2018, for an energy system that no longer exists. Government has recognised this, commissioned advice on where the line should move, and committed to a baseline for every Ofgem licensee by the end of 2030. That work is welcome and it is also four years away, and the scheme chosen as its foundation does not currently reach operational technology.

Operators that have already been targeted do not have four years, and press analysis published a month after the incident concluded that Britain’s small power plants face continued cyber risk. [7] The organisations that come through the next phase in good order will be those that treat the 2030 baseline as the minimum they will eventually be asked to evidence, and build OT security ahead of it on their own timetable.

References

  1. The Register, “Iran-linked cyberattack shut down a UK power plant”, 24 August 2026, carrying the Department for Energy Security and Net Zero statement on the small-scale energy generator incident. https://www.theregister.com/security/2026/08/24/iran-linked-cyberattack-shut-down-a-uk-power-plant/ First reported by The Sunday Telegraph, 22 August 2026 (paywalled).
  2. The Network and Information Systems Regulations 2018, Schedule 2, U.K. Essential Services and Threshold Requirements. https://www.legislation.gov.uk/uksi/2018/506/schedule/2 (revised text as in force at 2 September 2026).
  3. Department for Energy Security and Net Zero and Ofgem, “Reshaping cyber regulation in downstream gas and electricity: government response”, 5 August 2026. https://www.gov.uk/government/consultations/whole-energy-cyber-resilience-requirements-reshaping-cyber-regulation-in-downstream-gas-and-electricity
  4. Department for Energy Security and Net Zero, Ofgem, NCSC and NESO, “Energy Sector Cyber Security Strategy”, 28 May 2026. https://www.gov.uk/government/publications/energy-sector-cyber-security-strategy/energy-sector-cyber-security-strategy
  5. Department for Energy Security and Net Zero and Ofgem, “Reshaping cyber regulation in downstream gas and electricity: consultation document”, 27 March 2026. https://assets.publishing.service.gov.uk/media/69c51142471d520038d0f68d/whole-energy-resilience-consultation-document.pdf
  6. CERT Polska, “Energy Sector Incident Report – 29 December”, published January 2026. https://cert.pl/en/posts/2026/01/incident-report-energy-sector-2025/ (full report: https://cert.pl/uploads/docs/CERT_Polska_Energy_Sector_Incident_Report_2025.pdf). See also CERT Polska, “Follow-Up Report of the December 2025 Energy Sector Incident”, August 2026. https://cert.pl/en/posts/2026/08/incident-follow-up-report-energy-sector-2025/
  7. The Guardian, “UK’s small power plants face continued cyber risk after Iran-linked hack”, 27 August 2026. https://www.theguardian.com/business/2026/aug/27/uk-small-power-plants-risk-cyber-attacks-iran-hack
  8. Cyber Security and Resilience (Network and Information Systems) Bill, HL Bill 32, introduced to Parliament 12 November 2025. Lords Second Reading 14 July 2026, Lords Committee Stage from 1 September 2026. https://bills.parliament.uk/bills/4035
  9. National Cyber Security Centre, Cyber Essentials. https://www.ncsc.gov.uk/cyberessentials/overview
  10. M. Davis, IOActive, “Advanced Metering Infrastructure (Smart Grid) Device Security”, Black Hat USA 2009. https://blackhat.com/presentations/bh-usa-09/MDAVIS/BHUSA09-Davis-AMI-SLIDES.pdf
INSIGHTS | September 25, 2026

One Exposure, Many Actors: What the NCSC’s OT Alert Adds to the AA26-097A Picture

Key Takeaways

  • On 27 August 2026, the NCSC published an Alert warning of increased targeting of operational technology (OT) systems across multiple sectors globally, including in the UK, carried out by a range of threat actors and resulting in some limited real-world disruption [1].
  • The Alert is deliberately unattributed. It should not be read as an extension of joint advisory AA26-097A, which attributes a separate and well-documented PLC exploitation campaign to Iranian-affiliated actors [2].
  • Three separate bodies of reporting published between April and August 2026, covering Iranian-affiliated PLC exploitation, Russian FSB Centre 16 router targeting, and unattributed activity against water sector controllers, converge on the same access route of systems reachable directly from the public internet.
  • The FBI and EPA have reported that similarities in network configurations supplied by third parties allowed attackers to repeat successes across multiple victims, making integrator and supplier architecture a first-order concern rather than a downstream one [3].
  • The Alert lands five days before the UK Cyber Security and Resilience Bill reaches Lords Committee Stage on 1 September 2026, placing OT exposure in front of regulators, boards and legislators simultaneously [4].

Why the NCSC’s Alert Matters Now

The NCSC classified its 27 August publication as an Alert rather than guidance. That distinction carries weight. The organisation states that it has been engaging with affected sectors directly in response to recent targeting and is publishing the material to support national resilience efforts, which indicates that the advice follows live incident handling rather than horizon scanning [1].

The substance is uncomfortable for anyone who has treated OT exposure as a solved problem. The NCSC reports increased targeting of OT systems across multiple sectors globally, including in the UK, conducted by a range of threat actors, with some limited real-world disruption already recorded [1]. It also sets out a broader judgement. Against a backdrop of technology-enabled uplifts in offensive capability and increased geopolitical instability, the threat from state use of offensive cyber, including outside of conflict, has almost certainly increased [1].

The timing compounds the message. The Alert arrives within four months of joint advisory AA26-097A, seven weeks after an international advisory on Russian state targeting of network devices, and four weeks after an FBI and EPA announcement describing degraded water operations in at least seven US states [2][3][5]. Regulators are moving in parallel. The Cyber Security and Resilience Bill is scheduled to enter Lords Committee Stage on 1 September 2026, with Royal Assent expected later in the year [4].

What Does the NCSC Alert Actually Say?

The Alert sets out eight actions. Several restate established practice:

  • Build a definitive view of OT architecture including all assets, communications pathways and external connections
  • Replace default credentials and enforce unique administrator accounts with multi-factor authentication where supported
  • Harden the OT boundary and keep gateways, firewalls, routers and remote access appliances within vendor support
  • Segment OT, management and business networks
  • Maintain tested, ransomware-resistant backups of configurations, controller logic and critical engineering data [1]

Two items deserve closer attention because they move beyond network-layer control.

The first concerns device state. The NCSC advises that OT devices be operated in a condition that prevents remote programming during normal operations, ensuring PLCs are not left in PROGRAM or other maintenance modes and that controller logic uses password-based write protection or equivalent mechanisms to prevent unauthorised changes from malicious endpoints [1]. This is a control on the device itself, not on the path to it, and it assumes the network boundary may fail.

The second concerns protocols. The Alert recommends migrating industrial protocols to secure variants where available, naming DNP3 to DNP3-SAv5, CIP to CIP Security, Modbus to Modbus Security, and OPC DA to OPC UA, while removing telnet and SNMP versions 1 and 2 from management use [1]. Where no secure alternative exists, insecure protocols should be confined to isolated network segments.

The Alert also addresses organisations without OT estates, noting a continuing pattern of disruptive activity against internet-exposed systems and edge devices across all sectors, and directing readers to maintain an accurate inventory of internet-facing systems, retire end-of-life equipment and monitor for unexpected configuration changes or outbound connections [1]. It points UK organisations towards the NCSC’s free Early Warning service and frames the Cyber Assessment Framework as the mechanism through which boards should seek assurance [1].

Notably, the Alert names no threat actor.

How Does This Connect to AA26-097A, and Where Does It Not?

This is the point at which analysis most often goes wrong, and the distinction matters more than the similarity.

Advisory AA26-097A, first published on 7 April 2026 and updated on 22 July 2026, attributes an active campaign to Iranian-affiliated APT actors exploiting internet-connected PLCs across US critical infrastructure. The July update broadened the observed manufacturer scope from Rockwell Automation/Allen-Bradley to include Schneider Electric and Siemens controllers, added detection guidance for malicious changes in reusable code modules within Rockwell PLC programs, and brought the Department of the Treasury onto the authoring byline alongside CISA, the FBI, NSA, EPA, the Department of Energy and US Cyber Command’s Cyber National Mission Force [2].

Separately, an international advisory published in July 2026, co-sealed by the NCSC alongside 18 partner agencies from 12 countries, attributes sustained targeting of poorly configured routers to Russian Federal Security Service Centre 16, tracked variously as Berserk Bear, Energetic Bear, Dragonfly, Ghost Blizzard and Static Tundra. That activity centres on internet-wide scanning for devices accepting default or weak SNMP community strings, followed by exfiltration of device configuration files [5].

Separately again, the FBI and EPA issued a public service announcement on 30 July 2026 describing unattributed malicious cyber actors targeting internet-facing Rockwell Automation/Allen-Bradley MicroLogix 1100 and 1400 PLCs. Water and wastewater utilities in at least seven states reported incidents from 27 July 2026 onwards. The actors changed device IP addresses and set passwords, producing loss of view and, in some cases, loss of function. Reported operational effects included loss of pressure and flooding, with the announcement noting that pressure loss in water systems could potentially allow untreated groundwater to seep into pipes [3].

Four publications carry three different attribution states. One names Iranian-affiliated actors, one names a Russian intelligence unit, and two describe activity the authoring agencies have chosen not to attribute. Collapsing these into a single narrative would be an analytical error, and one that regulated operators cannot afford to make in reporting or board briefings.

What survives the separation is the access route. In every case the initial condition is the same, namely a control system, a management interface or an edge device reachable from the public internet and frequently protected by default, weak or absent credentials. The NCSC’s phrasing, that this activity is being carried out by a range of threat actors, is the more useful framing for defenders precisely because it removes the actor from the risk calculation. Exposure is exploitable by whoever finds it first.

Who is Affected by the NCSC’s OT Alert?

CNI operators with field-deployed OT

Any organisation with internet-exposed OT could be affected. The NCSC is explicit that organisations should not assume their OT is inaccessible from the internet without verifying it, since unintended exposure can arise through misconfigurations, legacy connections or unmanaged assets [1]. Water, wastewater and energy operators with geographically distributed sites and cellular field connectivity carry the highest concentration of this risk.

System integrators and managed service providers

The FBI and EPA observed that across several victims, similarities in network setups provided by third parties may give attackers the opportunity to multiply successes where vulnerable configurations recur across a supplier’s customer base [3]. A single integrator’s default deployment pattern becomes a repeatable attack template. This finding maps directly onto the critical supplier designation powers in the Cyber Security and Resilience Bill.

Organisations without OT

The Alert is explicit that the broader pattern of disruptive activity against internet-exposed systems and edge devices affects all sectors [1]. Routers, firewalls, VPN concentrators and remote access appliances present the same fundamental exposure.

Boards and regulated entities across jurisdictions

UK operators face the CAF as the assurance framework of record and the Cyber Security and Resilience Bill as the coming statutory instrument [1][4]. EU operators are working to NIS2. US operators sit within the CISA advisory and directive framework, including binding requirements on end-of-support edge devices [6]. The technical remediation is common across all three, and only the reporting obligations differ.

What Makes This Exposure So Difficult to Eliminate?

The mitigations in the NCSC Alert are not novel, and that is the difficulty. Every one of the eight actions was recognised practice before August 2026. Their repeated publication indicates a gap between recommendation and implementation rather than a gap in knowledge.

Three factors sustain that gap.

Asset visibility remains hard in OT. Exposure is frequently unintended, arising from a commissioning shortcut, a supplier’s remote support link, or a cellular modem installed to solve an operational problem years earlier. An operator can hold an accurate architecture diagram and still be exposed through an asset that diagram never captured.

Integrity attacks defeat availability-focused monitoring. AA26-097A describes actors using legitimate vendor engineering software to alter controller logic and falsify operator displays, and the FBI reported at least one organisation discovering modified PLC project files after noticing ladder logic discrepancies across several sites [2][3]. Where the control room’s picture of the process is itself manipulated, conventional uptime monitoring will report normality.

Remediation carries operational cost. Removing a PLC from direct internet exposure, migrating a protocol, or replacing an end-of-life gateway involves planned downtime in environments where downtime is the primary risk being managed. This is where technical recommendation meets capital planning, and where accountability for the outcome frequently disperses.

How IOActive Can Help

The NCSC’s Alert describes a condition rather than an incident. That condition is assets reachable from the internet that the owner did not know were reachable, protected by credentials the owner did not know were still default. Verifying that condition is an assessment problem before it is a remediation problem, and it spans the OT estate, the edge estate and the third parties with standing access to both.

IOActive has operated in industrial control environments since building the first proof-of-concept worm against the smart grid in 2009 [9], and has helped define standards and best practices including NIST 800-53 and 800-37. The services below map to the specific gaps this Alert exposes.

Full Stack Security Assessments

The Alert’s first action, to build a definitive view of OT architecture and not assume OT is unreachable without verifying it, is precisely the work most assessments stop short of. Our Full Stack assessments examine the whole environment rather than a single layer, covering internet-facing controllers and HMIs, the OT/IT boundary, the cellular modem paths that frequently provide field sites with their only route to the internet, and the firmware and silicon of the devices themselves through penetration testing, reverse engineering, side-channel analysis and fault injection.

Two of the Alert’s actions sit at the device rather than the network layer. Those are confirming controllers are not left in PROGRAM mode, and migrating industrial protocols to secure variants such as DNP3-SAv5, CIP Security, Modbus Security and OPC UA. These are testable conditions, not policy statements, and they are where an assessment either produces evidence or produces reassurance. As we set out in Cyber Attack Trends 2026, the environments organisations depend on most are routinely the ones they monitor least.

Supply Chain Integrity

The FBI and EPA finding that similar third-party network configurations allowed attackers to repeat successes across a supplier’s customer base is the most consequential detail in the current reporting, and the least addressable by any single operator acting alone [3]. It also has a direct precedent in our analysis of the Polish energy sector incident, which documented more than 30 facilities breached through the same pattern of internet-facing VPN portals without MFA, where credential reuse across sites turned one compromised account into a fleet-wide problem.

Our Supply Chain Integrity work assesses the security posture of technology providers and critical third parties, covering firmware, embedded systems, remote access arrangements and procurement processes, so that inherited risk is identified before it becomes a shared incident. For UK operators, this maps onto the critical supplier designation powers in the Cyber Security and Resilience Bill [4].

Red Team and Purple Team Services

The Alert notes that OT environments are typically static and predictable, which makes baseline monitoring highly effective at identifying unauthorised activity [1]. The question is whether a given deployment actually achieves that in practice. Adversarial testing is how an operator finds out before an adversary does, particularly against integrity attacks such as altered controller logic and falsified operator displays, which availability-focused monitoring is not built to catch. Our Purple Team work translates those findings into measurable detection improvements, and we set out the distinction between the two approaches in Red Team vs Penetration Testing.

Advisory Services

The eight actions in this Alert have all been published before, in various forms, and that is the problem worth solving. When we examined the Minnesota water utilities in When the Advisory Arrives First, the gap was not the absence of a warning but the absence of an owner for acting on it.

Our Advisory Services cover programmatic security review, security programme development and management, and Virtual CISO support. They turn an alert into a prioritised remediation plan with named accountability, and produce the evidence boards need for CAF or equivalent regulatory assurance. That work is increasingly shaped by converging regimes across all three jurisdictions, as we examined in our analysis of the UK Energy Sector Cyber Security Strategy and the Five Eyes statement on AI and cyber risk. The latter is directly relevant to the NCSC’s judgement here that technology-enabled uplifts in capability are part of why the threat has increased [1].

If you would like to discuss how your organisation’s internet-facing OT and edge exposure measures up against the activity described in this Alert, we welcome the conversation.

  1. Verify exposure rather than assuming its absence. Build or refresh a definitive view of the OT architecture covering all assets, communications pathways and external connections, and validate it against external scanning results rather than against documentation [1].
  2. Remove control system devices from direct internet reachability. Broker all remote access through a secure gateway or jump host so that OT is never directly exposed to external networks, and secure cellular modems used for field connectivity with strong authentication and logging [1][3].
  3. Eliminate default and shared credentials on OT and edge devices. Enforce unique administrator accounts, enable multi-factor authentication where supported, and use key-based authentication in preference to passwords where the protocol allows [1].
  4. Enforce device-level write protection. Confirm that PLCs are not left in PROGRAM or maintenance modes during normal operations and that controller logic is protected against unauthorised modification [1].
  5. Validate controller logic integrity. Use vendor integrity checking tools to compare running programs against known-good logic, and verify that backups are free of malicious logic before restoration [3].
  6. Retire or isolate end-of-support edge devices. Maintain a rolling replacement forecast reviewed against ownership and procurement, and apply compensating controls with firm decommission dates where replacement is delayed [3][6].
  7. Baseline and monitor OT network traffic. OT environments are typically static and predictable, which makes baseline monitoring effective at identifying communication with PLCs and HMIs from unexpected devices, networks or routes [1].
  8. Rehearse manual operation and recovery. Test the capability to revert to manual control, isolate affected systems and restore from trusted backups, and treat those exercises as evidence for CAF or equivalent regulatory assurance [1][3].

Conclusion

The NCSC’s August Alert does not describe a new technique, a new vulnerability class or a new adversary. It describes a durable condition that a widening set of actors continues to find and exploit, namely control systems and edge devices reachable from the open internet. The value in reading it alongside AA26-097A is not in merging the two, but in observing that campaigns with entirely different sponsors, objectives and levels of sophistication are arriving at the same door.

That has a practical consequence for how operators prioritise. Attribution shapes the diplomatic and sanctions response, but it does not change the remediation. An internet-facing PLC with a default password represents identical risk whether the entity that finds it is a state intelligence service or an opportunistic scanner. As the UK’s statutory regime moves towards Royal Assent and the EU and US frameworks tighten in parallel, the operators best positioned will be those who can evidence what they expose to the internet, and who owns the answer.

References

  1. National Cyber Security Centre, Disruptive cyber activity highlights risk from internet-exposed systems and edge devices, 27 August 2026. https://www.ncsc.gov.uk/news/disruptive-cyber-activity-highlights-risk-from-internet-exposed-systems-and-edge-devices
  2. CISA, FBI, NSA, EPA, DOE, US Cyber Command CNMF and Department of the Treasury, Joint Cybersecurity Advisory AA26-097A, Iranian-Affiliated Cyber Actors Exploit Programmable Logic Controllers Across US Critical Infrastructure, published 7 April 2026, updated 22 July 2026. https://www.cisa.gov/news-events/cybersecurity-advisories/aa26-097a
  3. Federal Bureau of Investigation and Environmental Protection Agency, Malicious Cyber Actors Targeting Water and Wastewater Sector Internet-Facing Programmable Logic Controllers, Causing Operational Disruptions, 30 July 2026. https://www.fbi.gov/investigate/cyber/alerts/2026/malicious-cyber-actors-targeting-water-and-wastewater-sector-internet–facing-programmable-logic-controllers-causing-operational-disruptions
  4. UK Parliament, Cyber Security and Resilience (Network and Information Systems) Bill, HL Bill 32, Lords Second Reading 14 July 2026, Committee Stage 1 September 2026. https://bills.parliament.uk/bills/4035
  5. National Cyber Security Centre, UK and Allies urge critical sectors to improve defences against Russian intelligence targeting, July 2026. https://www.ncsc.gov.uk/news/uk-and-allies-urge-critical-sectors-to-improve-defences-against-russian-intelligence-targeting
  6. CISA, Reducing the Attack Surface for End-of-Support Edge Devices and Binding Operational Directive 26-02. https://www.cisa.gov/resources-tools/resources/reducing-attack-surface-end-support-edge-devices
  7. NCSC-UK, FBI and CISA, Secure Connectivity Principles for Operational Technology. https://www.ncsc.gov.uk/collection/operational-technology/secure-connectivity
  8. National Cyber Security Centre, Cyber Assessment Framework. https://www.ncsc.gov.uk/collection/cyber-assessment-framework
  9. M. Davis, IOActive, Advanced Metering Infrastructure (Smart Grid) Device Security, Black Hat USA 2009. https://blackhat.com/presentations/bh-usa-09/MDAVIS/BHUSA09-Davis-AMI-SLIDES.pdf
ADVISORIES | August 7, 2024

IOActive Security Advisory | PLANET Networking – Vulnerabilities Identified

Affected Product

  • IGS-4215-16T2S

Firmware Version

  • 1.305b210528

Background

IOActive had the chance to access the IGS-4215-16T2S device. IOActive identified three vulnerabilities which need attention.

Timeline

  • 2022-09-29: IOActive discovers the vulnerabilities
  • 2023-03-29: IOActive informs Planet Technology about the identified vulnerabilities
  • 2023-12-13: Planet released a new firmware version (1.305b231218) informing IOActive that the vulnerabilities are fixed
  • 2024-01-09: IOActive notifies the vulnerability to INCIBE, Spanish CERT
  • 2024-02-16: IOActive confirm that the vulnerabilities were fixed after retesting them in the new firmware version
  • 2024-03-21: INCIBE shared the CVEs assigned with IOActive
  • 2024-08-07: IOActive advisory published
  • NOTE : While publishing this disclosure, IOActive had retested version FW-IGS-4215-16T2S_v1.305b231218.bix with hash 6e4ea892dc0d203c83ff02a2cba13e83. This version had the fixes. PLANET Technology published a firmware FW-IGS-4215-16T2S_v1.305b240227.bix with the hash abe64b8a62ebf339fb404fd85c0081b. They had informed that the findings have been fixed in this version. IOActive has not reviewed this firmware.
ADVISORIES | July 25, 2024

IOActive Security Advisory | Fortinet FortiGate – Cross-site Scripting in SSL VPN

Affected Products

VersionAffected
FortiOS 7.47.4.0 through 7.4.3
FortiOS 7.27.2.0 through 7.2.7
FortiOS 7.07.0.0 through 7.0.13
FortiOS 6.46.4 all versions
FortiProxy 7.47.4.0 through 7.4.3
FortiProxy 7.27.2.0 through 7.2.9
FortiProxy 7.07.0.0 through 7.0.16


Background

Fortinet, Inc. (Fortinet) is a global leader of cybersecurity solutions and services that provides protection against cyber threats. It is a company that develops and sells security products and solutions, such as firewalls, endpoint security, intrusion prevention systems, web filtering, antivirus, sandbox, and VPN.

FortiGate is a network security device that provides protection against cyber threats. The device can perform various functions, such as, firewall, intrusion prevention system, web content filtering, antivirus, sandbox and VPN and is part of the Fortinet Security Fabric, which integrates different security products and services into a unified and automated platform.


Timeline

  • 2023-11-16: IOActive discovers the vulnerability
  • 2023-11-22: IOActive informs Fortinet about the identified vulnerability
  • 2024-01-12: Fortinet acknowledges the issue
  • 2024-04-26: CVE ID pre-reserved by Fortinet
  • 2024-07-10: Advisory published by Fortinet
  • 2024-07-25: IOActive advisory published
ADVISORIES | June 21, 2024

IOActive Security Advisory | MásMóvil Comtrend Router –  Multiple Vulnerabilities

Affected Products

  1. MásMóvil Comtrend Router – Version: ES_WLD71-T1_v2.0.201820
    1. HW Version: GRG-4280us
    1. FW Version: QR51S404
    1. SW Version: MMV-C04_R10

Timeline

  • 2023-08-24: IOActive discovers vulnerability
  • 2023-09-12: IOActive begins vulnerability disclosure with affected parties
  • 2024-06-10: The corresponding CNA released the CVEs to public domain.
  • 2024-06-21: IOActive advisory published
EDITORIAL, RESEARCH | April 25, 2024

Bits to Binary to Bootloader to Glitch: Exploiting ROM for Non-invasive Attacks

In this paper, we explore how ROM can be leveraged to perform a non-invasive attack (i.e., voltage glitching) by a relatively unsophisticated actor without a six-figure budget. We begin by explaining what ROM is, why it is used, and how it can be extracted.

What exactly is ROM?

Put simply, Read-Only Memory (ROM) is a type of Non-Volatile Memory (NVM) that is constructed as physical structures within chips. The structures are patterned as ones and zeroes on one, and only one, of several layers of the chip. Why just one? Cost. ROM is real hardware, and making any hardware changes in the layout of a chip is very expensive.

The fact that ROM is physically encoded in a chip makes it uniquely reliable and thus appropriate for critical functions, such as boot code execution. ROM is infinitely more reliable than NVM that relies on an electrical charge, like Flash.

The following table provides a brief overview of memory classes.

Table 1. Summary of memory classes, type, and uses

How can you extract data from ROM?

If there is no protection on the device (i.e., it is embedded on a development board), then it is simple to access the data and dump it as a binary (.bin) file. By doing so, we have essentially extracted the final code, as opposed to the raw bits. This means that the code is in an understandable format (no need to decrypt or descramble) and can be analyzed using standard software reverse engineering tools, like IDA Pro or Binary Ninja, to isolate a weakness in the bootloader.

If the ROM is protected, then there is the option to physically deprocess sample chips (more on that later) and extract the raw bits as ones and zeroes. The process is very skill dependent; however, it is possible to carry out on a shoestring budget depending on the age of the chip technology. In some cases, only a polishing wheel, a handheld polishing jig, and an optical microscope are needed.

Reading out the raw bits is only the first step of the process, as these bits need to be further analyzed and manipulated to properly understand the code. The complexity of reverse engineering will vary depending on the following:

Is the ROM scrambled?

Scrambling is when the data is ‘mixed-up’ at the periphery of the memory block. In this case, it is enough to study the peripheral circuitry to make sense of the data.

Figure 1. Normal (unscrambled) output
Figure 2. Scrambled output

The ordering may also vary byte-to-byte, making reverse engineering more difficult.

Is the ROM encrypted?

Encryption is far more difficult to reverse engineer because the data is routed out of the memory and into the CPU logic, which is usually vast and, on its face, random. The data will be routed to the decryption circuitry, which may only be a few dozen logic cells.

Finding the decryption circuitry in a sea of one hundred thousand logic cells with no direction on where to start is an extremely difficult task. It may be necessary to reverse engineer the entire CPU logic; however, there are isolation techniques like thermal or photon emission that can help identify a specific area of interest on the chip. Using such techniques, the chip is instructed to repeatedly decrypt data while the entire chip is monitored for heat or light emissions, revealing the area of the chip that is performing the decryption. This smaller area of the chip then becomes the focus of reverse engineering.

Is the ROM both scrambled and encrypted?

If the ROM is both scrambled and encrypted, recovering the data will require analysis of the addressing logic and reverse engineering some if not all of the CPU logic. If the raw data is encrypted, the physical bit pattern will look the same, whether it is scrambled or not.

How do you deprocess a chip?

Deprocessing is the physical removal of layers from a finished chip using chemical and mechanical techniques. The process is necessarily destructive and can be used to remove one or more layers, depending on the target.

Consider the following example chip:

Figure 3. Example chip cross-section showing metal layers and transistors

We can see that the chip is constructed of many layers of copper circuitry, all embedded in an insulator (glass-type material). Transistors are literally the building blocks of digital components and are fabricated on the silicon substrate at the bottom of the chip. Therefore, the ROM transistors will be located on the bottom as well. The raw bits we are looking for (the ROM encoding layer) will likely be at the Contact, Metal 1, or Via 1 layer (between Metal 1 and Metal 2), but we won’t know for sure until we start destroying some chips.

If we have the time and sufficient samples, we can start by removing all of the layers from one chip in order to analyze the floorplan. Based on this analysis, we can map out where the memories are located and even identify what types of memories are present, such as Flash, SRAM, DRAM, or ROM. This will help identify the specific area of the chip to focus on when attempting to extract the raw bits. In addition, we could also cross-section a chip at the location of the ROM to help determine which layer contains the bit encoding to guide our work.

If we don’t have the time or the samples, we can just go ahead and carefully deprocess a single chip, and at some point, the ROM bits will appear. But if we deprocess too far, we will go past the bit encoding layer and lose the data.

For our work, we will use the most basic and fastest technique—mechanical polishing. While many argue that mechanical polishing is the most effective method for deprocessing chips, it is also the most skill dependent.

We can polish in several ways (in order of increasing sophistication and cost):

  1. Manual finger polishing: The decapsulated chip is placed on the fingertip and polished on a static plate or piece of glass.
  2. Turntable finger polishing: Similar to manual but uses a rotating platen to expedite the polishing process (and eliminate Repetitive Strain Injury!).
  3. Manual polishing with fixture (jig): Uses a rotating platen in conjunction with a polishing fixture that can be adjusted to compensate for non-planarity.
  4. Semi-automated polishing: Uses a purpose-built system with control over:
    1. Platen speed
    1. Sample planarity
    1. Force applied to sample
    1. Sample rotation (in addition to platen rotation)

In this example we used the third approach because a turntable accelerates progress, and a polishing jig offers fine angle control. Additionally, the manual polishing table and jig, as well as the abrasives involved, are relatively low-cost items, keeping the approach within reach of a skilled and motivated hobbyist.

Figure 4. A decapsulated chip mounted to the polishing stub
Figure 5. The stub attached to the polishing jig while being polished

Determining when to stop polishing (end pointing) is difficult; however, when we hit the ROM encoding layer, we should see some kind of pattern under an optical microscope, even at 5x magnification.

The image below was taken at 20x magnification, and we can categorically say that we have reached the right layer.

Figure 6. Corner of ROM exposed at bit encoding layer

The bits appear as white dots from above, because they are bullet-shaped Tungsten interconnects, a little like the contacts shown in the following cross-section images:

Figure 7. ROM cross-section fully processed (left) and deprocessed to the bit encoding layer (right)
Figure 8. Sample area for initial visual inspection

We can see from a very high-level visual inspection that the ROM cannot possibly be encrypted, due to the distribution of ones versus zeroes. If the data was properly encrypted, then the distribution would appear random; however, a visual assessment is sufficient to confirm a lack of entropy without the need to formally calculate[1] it with binwalk[2] or another tool. We can conclude that although the data may be scrambled, it is not encrypted. There is enough evidence to tell us that if we extract the raw bits, we can derive the addressing to then get us back to an understandable binary.

For now, we don’t need to carefully analyze the addressing circuit; all we need is to determine if there is any scrambling in the addressing logic. We can do this visually.

Figure 9. Sample area of decoding/addressing circuit (bottom)
Figure 10. Sample area of decoding/addressing circuit (left)
Figure 11 Sample area of decoding/addressing circuit (between blocks)

When we isolate a small area of the decoding/addressing circuitry at any point (bottom, left, or between the blocks), it is perfectly repeated. This proves that the ROM is not scrambled, and all we need to do is to work out how the bits are read to recreate the full binary. That, and extract the raw bits, of course.

No Scrambling 😊

No Encryption 😊

How do you extract the raw bits?

It is preferable that we automate the extraction process, as the ROM’s capacity is 16 KB (128,000 single bits), which is far too much to extract manually. First, we must determine if our optical images are good enough to reliably extract the raw bits. If not, we may need to use a Scanning Electron Microscope (SEM) to obtain higher resolution, higher contrast images.

Figure 12. Sample area of raw bits imaged optically (top) and by SEM (bottom)

Clearly there is a huge difference in resolution and, more importantly, contrast between the two types of images. It’s obvious that using SEM images would expedite the extraction process, but let’s see if we can use the optical images and do this on a shoestring budget.

First, we need to optimize the optical test image with photo editing software to maximize our chances of success. A good start is always to use the filters in Photoshop such as ‘Noise – Despeckle’ and ‘Noise – Dust and Scratches.’ The final step would be to manipulate the levels to maximize the contrast.

Figure 13. Screenshots showing Adobe Photoshop noise filters being applied
Figure 14. Sample area of raw bits imaged optically and filtered/optimized

Perhaps quite surprisingly, simply by filtering and adjusting the levels of the optical image, we can almost end up with the same result as with the SEM.

Figure 15. Plot of unfiltered optical image
Figure 16. Plot of filtered optical image

From this simple test, we can conclude that any effective tool will be capable of reliably extracting the raw bits from our optical images.

Figure 17. Single block with bit extraction grid overlaid
Figure 18. Zoomed view of bits with extraction grid overlaid

Commercial software is available for semi-automated ROM bit extraction. The software measures the brightness of the area around the line intersections and compares that against a user-defined estimate for both a one and a zero. The software then assigns values to each area in which a bit exists, then exports the values to a text file. Below is the text extracted from this small piece of ROM. This is a fraction of one of 64 sections within the memory array, so some time is required for a full extraction. There is certainly an AI/ML opportunity here to expedite the process.

After repeating the process many times, we have the entire ROM in our hands, and we can move onto the next step: deriving how the bits are addressed. At this point, we will have a usable binary to work with in IDA Pro or Binary Ninja so we can understand the boot process and find some potential areas of weakness we can glitch.

Bits to Binary

As this is a chip with a known vulnerability, it was possible to dump the entire ROM via JTAG. We will use this dump to help us do two things:

  1. Deduce how the ROM is addressed
  2. Compare our physically extracted ROM with the JTAG dump to validate our process

To illustrate the analysis of our physically extracted dump, we will use the higher-resolution SEM images we acquired after the optical images were taken.

Let’s start by looking at the electrical dump of the ROM. The following output is the beginning and end of the ROM .bin, with the end looking very much like a checksum. We know this is commonly used by this manufacturer, so after many zero bytes, there are two bytes of data at the very end of the file.

Figure 19. Hex dump output of the start (top) and end (bottom) of the ROM .bin
Figure 20. Bottom section of ROM SEM stitch with checksum bits annotated
Figure 21. Close-up showing that the three bits are not in the same row. One on the first row, then two on the second row (the red line is perfectly parallel)

From the fact that we have the two-byte checksum (0105) in hex, and that the corresponding raw bits (0000 0001 0000 0101) are not in a linear pattern, then we must assume that there is some flipping/mirroring happening on the bit addressing. The fact that the bits are split over two rows also gives us a clue.

Now our checksum is beginning to make sense. With a checksum of 0105 (0000 0001 0000 0101), there must only be one way to read it. Essentially, we are looking for how the three ones are addressed.

First, we can see that the three bits are all on the same bit column, so we can ignore the rest. It makes things easier to visualize by annotating all of the bit columns, then highlighting the only column (column 0) we care about in yellow. The values are now much easier to read by eye, and we can see the direction in which they are read by the memory array.

Figure 22. Right side of checksum area annotated with columns, binary values, and hex
Figure 23. Entire width of checksum area annotated with columns, binary values, and hex

We now see that 0105, albeit not in a logical order for a human. There is one question mark remaining: Do we assume that we read the left side in reverse first (01) followed by the second (05)? There we have a simple 50% chance of being correct, and to find out, we can apply that to the more densely populated areas of ROM.

Figure 24. Opposite end of ROM annotated with read order, binary values, and corresponding hex

The portion of ROM above shows the hex value along with the raw binary for the two-word width of the ROM array. The colored arrows illustrate the direction in which the bits are read from the .bin and how they are read from the raw bit image. The following is a closer view of one byte, where blue bits are logical ones and yellows are logical zeros:

the end of the ROM, annotated with read order and binary values

Finally, a binary!!!

The following image contains some dumped bytes from the target. This can be later be opened in the reversing tool of our choice, and after some preparation work, we can begin reverse engineering and identifying the potential weaknesses. In this case, as some readers might know, the target sample has a known vulnerability that can be exploited via fault injection. This vulnerability can allow an attacker with physical access to the device to retrieve the entire contents, even if the chip has been locked down.

Figure 26. Some bytes dumped from the target chip
Figure 27. Part of the boot process where CRP values are read and are controlling access to the debugging interfaces

Overall Conclusions

  • While a chip with a known vulnerability was used in this case study for comparative purposes, the same techniques can be applied to a chip without this vulnerability
  • The electrical version of the ROM dump matched 100% with the physically extracted version
  • Physical ROM bit extraction is skill-dependent, but can be carried out using a relatively basic toolset such as:
    • Basic polishing turntable
    • Handheld polishing jig
    • Diamond abrasives
    • Optical microscope
  • ROM binary extraction is dependent on:
    • Existence of encryption
    • Complexity of scrambling
    • Patience!
  • ROM binary analysis and isolation of glitching/fault injection points is possible
  • Electrical and electromagnetic fault injection techniques are skill- and chip-dependent; however, the bar of entry is relatively low (hundreds to thousands of dollars)

[1] https://resources.infosecinstitute.com/topics/cryptography/entropy-calculations/
[2] https://github.com/ReFirmLabs/binwalk

INSIGHTS, RESEARCH | April 17, 2024

Accessory Authentication – part 3/3

This is Part 3 of a 3-Part series. You can find Part 1 here and Part 2 here.

Introduction

In this post, we continue our deep dive comparison of the security processors used on a consumer product and an unlicensed clone. Our focus here will be identifying and characterizing memory arrays.

Given a suitably deprocessed sample, memories can often be recognized as such under low magnification because of their smooth, regular appearance with distinct row/address decode logic on the perimeter, as compared to analog circuitry (which contains many large elements, such as capacitors and inductors) or autorouted digital logic (fine-grained, irregular structure).

Identifying memories and classifying them as to type, allows the analyst to determine which ones may contain data relevant to system security and assess the difficulty and complexity of extracting their content.

OEM Component

Initial low-magnification imaging of the OEM secure element identified 13 structures with a uniform, regular appearance consistent with memory.

Higher magnification imaging resulted in three of these structures being reclassified as non-memory (two as logic and one as analog), leaving 10 actual memories.

Figure 1. Logic circuitry initially labeled as memory due to its regular structure
Figure 2. Large capacitor in analog block

Of the remaining 10 memories, five distinct bit cell structures were identified:

  • Single-port (6T) SRAM
  • Dual-port (8T) SRAM
  • Mask ROM
  • 3T antifuse
  • Floating gate NOR flash

Single-port SRAM

13 instances of this IP were found in various sized arrays, with capacities ranging from 20 bits x 8 rows to 130 bits x 128 rows.

Some of these memories include extra columns, which appear to be intended as spares for remapping bad columns. This is a common practice in the semiconductor industry to improve yield: memories typically cover a significant fraction of the die surface and thus are responsible for a large fraction of manufacturing defects. If the device can remain operable despite a defect in a memory array, the overall yield of usable chips will be higher.

Figure 3. Substrate overview of a single-port SRAM array
Figure 4. Substrate closeup view of single-port SRAM bit cells

Dual-port SRAM

Six instances of this IP were found, each containing 320 bit cells (40 bytes).

Figure 5. Dual-port SRAM cells containing eight transistors

Mask ROM

Two instances of this IP were found, with capacities of 256 Kbits and 320 Kbits respectively. No data was visible in a substrate view of the array.

Figure 6. Substrate view of mask ROM showing no data visible

A cross section (Figure 7) showed irregular metal 1 patterns as well as contacts that did not go to any wires on metal 1, strongly suggesting this was a metal 1 programmed ROM. A plan view of metal 1 (Figure 8) confirms this. The metal 1 pattern also shows that the transistors are connected in series strings of 8 bits (with each transistor in the string either shorted by metal or not, in order to encode a logic 0 or 1 value), completing the classification of this memory as a metal 1 programmed NAND ROM.

Figure 7. Cross section of metal 1 programmed NAND ROM showing irregular metal patterns and via with unconnected top
Figure 8. Top-right corner of one ROM showing data bits and partial address decode logic

IOActive successfully extracted the contents of both ROMs and determined that they were encrypted. Further reverse engineering would be necessary to locate the decryption circuitry in order to make use of the dumps.

Antifuse

Five instances of this IP were found, four with a capacity of 4 rows x 32 bits (128 bits) and one with a capacity of 32 rows x 64 bits (2048 bits).

The bit cells consist of three transistors (two in series and one separate) and likely function by gate dielectric breakdown: during programming, high voltage applied between a MOSFET gate and the channel causes the dielectric to rupture, creating a short circuit between the drain and gate terminals.

Antifuse memory is one-time programmable and is expensive due to the very low density (significantly larger bit cell compared to flash or ROM); however, it offers some additional security because the ruptured dielectric is too thin to see in a top-down view of the array, rendering it difficult to extract the contents of the bit cells. It is also commonly used for small memories when the complexity and re-programmability of flash memory is unnecessary, such as for storing trim values for analog blocks or remapping data for repairing manufacturing defects in SRAM arrays.

Figure 9. Antifuse array
Figure 10. Cross section of antifuse bit cells

Flash

A single instance of this IP was found, with a capacity of 1520 Kbits.

This memory uses floating-gate bit cells connected in a NOR topology, as is common for embedded flash memories on microcontrollers.

Figure 11. Substrate plan view of bit cells
Figure 12. Cross section of NOR Flash memory

Clone Component

Floorplan Overview

Figure 13. Substrate view of clone secure element after removal of metal and polysilicon

The secure element from the clone device contains three obvious memories, located at the top right, bottom left, and bottom right corners.

Lower-left Memory

The lower-left memory consists of a bit cell array with addressing logic at the top, left, and right sides. Looking closely, it appears to be part of a larger rectangular block that contains a large region of analog circuitry above the memory, as well as a small amount of digital logic.

This is consistent with the memory being some sort of flash (likely the primary code and data storage for the processor). The large analog block is probably the high voltage generation for the program/erase circuitry, while the small digital block likely controls timing of program/erase operations.  

The array appears to be structured as 32 bits (plus 2 dummy or ECC columns) x 64 blocks wide, by 2 bits * 202 rows (likely 192 + 2 dummy features + 8 spare). This gives an estimated usable array capacity of 786432 bits (98304 bytes, 96kB).

Figure 14. Overview of bottom left (flash) memory
Figure 15. SEM substrate image of flash memory

A cross section was taken, which did not show floating gates (as compared to the OEM component). This suggests that this component is likely using a SONOS bit cell or similar charge-trapping technology.

Lower-right Memory

The lower-right memory consists of two identical blocks side-by-side, mirrored left-to-right. Each block consists of 128 columns x 64 cells x 3 blocks high, for a total capacity of 49152 bits (6144 bits, 6 kB).

Figure 16. Lower-right memory

At higher magnification, we can see that the individual bit cells consist of eight transistors, indicative of dual-port SRAM—perhaps some sort of cache or register file.

Figure 17. Dual-port SRAM on clone secure element (substrate)
Figure 18. Dual-port SRAM on clone secure element (metal 1)

Upper-right Memory

The upper – right memory consists of a 2 x 2 grid of identical tiles, each 128 columns x 160 rows (total capacity 81920 bits/10240 bytes/10 kB).

Figure 19. Upper-right SRAM array

Upon closer inspection, the bit cell consists of six transistors arranged in a classic single-port SRAM structure.

Figure 20. SEM substrate image of 6T SRAM cells
Figure 21. SEM metal 1 image of 6T SRAM cells

Concluding Remarks

The OEM component contains two more memory types (mask ROM and antifuse) than the clone component. It has double the flash memory and nearly triple the persistent storage (combined mask ROM and flash) capacity of the clone, but slightly less SRAM.

Overall, the memory technology of the clone component is significantly simpler and lower cost.

Overall Conclusions

OEMs secure their accessory markets for the following reasons:

  • To ensure an optimal user experience for their customers
  • To maintain the integrity of their platform
  • To secure their customers’ personal data
  • To secure revenue from accessory sales

OEMs routinely use security chips to protect their platforms and accessories; cost is an issue for OEMs when securing their platforms, which potentially can lead to their security being compromised.

Third-party solution providers, on the other hand:

  • Invest in their own labs and expertise to extract the IP necessary to make compatible solutions
  • Employ varied attack vectors with barriers of entry ranging from non-invasive toolsets at a cost of $1,000 up, to an invasive, transistor-level Silicon Lab at a cost of several million dollars
  • Often also incorporate a security chip to secure their own solutions, and to in turn lock out their competitors
  • Aim to hack the platform and have the third-party accessory market to themselves for as long as possible
COLLATERAL | April 22, 2020

IOActive Corporate Overview

Research-fueled Security Assessments and Advisory Services

IOActive has been at the forefront of cybersecurity and testing services since 1998. Backed by our award-winning research, our services have been trusted globally by enterprises and product manufacturers across a wide variety of industries and in the most complex of environments.

Tailored to meet each unique organization’s requirements, IOActive services offer deep expertise and insight from an attacker’s perspective. 

COLLATERAL | April 17, 2020

IOActive Services Overview

Security services for your business, situation, and risks.

With our breadth and depth of services offerings across more environments than any other firm today, we can deliver specific, high-value recommendations based on your business, unique situation, and the risk you face. We are a pure-play security services provider, offering services across the spectrum to include: cybersecurity advisory, full-stack security assessments, SDL, red/purple team and security team development (training) services.

INSIGHTS | September 7, 2017

The Other Side of Cloud Data Risk

What I’m writing here isn’t about whether you should be in the cloud or not. That’s a complex question, it’s highly dependent on your business, and experts could still disagree even after seeing all of the inputs

What I want to talk about is two distinct considerations when looking at the risk of moving your entire company to the cloud. There are many companies doing this, especially in the Bay Area. CRM, HR, Email—it’s all cloud, and the number of cloud vendors totals in the hundreds, perhaps even thousands.

We’re pretty familiar with one type of risk, which is that between the internet and the cloud vendor. That list of risks looks something like this:

  • The vendor is compromised due to a vulnerability
  • An insider at the vendor leaves with a bunch of data and sells or posts it
  • Someone at the vendor misconfigures something and the internet finds it

The list goes on from there.

But the side of that cloud/vendor risk that companies don’t seem to be as aware of is their own insider access: while one risk is that the vendor does something stupid with your data, another is that your own employees do the same.

Considerations around insider access are numerous:

  • Employees with way too much access to sales, customer, employee, financial, and other types of data
  • No ability to know whether that data is being downloaded, by whom, and how much
  • No ability to detect that data on endpoints
  • No control of which endpoints access the data
  • No ability to control where that data is then sent

The situation in so many cloud-based companies is that they enable business by providing access to these cloud systems, but they don’t control which endpoints can reach that data. Users may get in through web apps, mobile apps, or other means. It’s application-based authentication that doesn’t know (or care) what type of device is being used: a 12-year-old desktop with XP on it, or an old Android device that hasn’t been updated in months or years.

Even worse is the false sense of security gained from spending millions on firewall infrastructure, while a massive percentage of the workforce either doesn’t work at the office or doesn’t hairpin back into the office through a VPN. The modern workforce—especially in these types of environments—increasingly connects from a laptop at home (or at a co-work site or coffee shop) directly to the backend, which is the cloud.

This puts us increasingly in a situation where most of the NetSec products we’ve been investing in for the last 15 years are moot, for the simple reason that fewer and fewer people are using the corporate network.

For cloud-based companies especially, it’s time to start thinking about AuthZ and AuthN from not just the user and app perspective, but from a complete endpoint perspective. What is the device, OS, patch levels, malware controls, etc., combined with the user auth, for any given access to an application and the data within?

The risk from a compromised vendor is significant, but it’s also largely outside of a company’s control. Anyone who’s been in security for a while knows that there are thousands of companies with X, Y, or Z certifications, or positive audit results when they absolutely shouldn’t have passed. It’s really hard to know how safe your data is when it’s sitting with hundreds of cloud vendors.

What you can do is to get better control over what your own people are doing with that same data, and that starts with understanding who’s accessing it, and from what devices.